Imc 602.2.1 materials within plenums
WitrynaAir plenums formed by gypsum boards shall not be incorpo-rated in air-handling systems utilizing evaporative coolers. 602.2.1 Materials within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.5, materials within ple-nums shall be noncombustible or shall be listed and labeled as having a flame spr ead index of not … Witryna2 paź 2015 · 602.2.1 Materials exposed within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.5, materials within plenums shall be …
Imc 602.2.1 materials within plenums
Did you know?
Witryna602.2.1 Materials within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.6, materials within ple - nums shall be noncombustible or shall have a flame spread indexofnotmorethan25andasmoke-developedindexofnot more than 50 when tested in accordance with ASTM E 84 or UL 723. Exceptions: 1. Rigid and flexible … Witryna28 paź 2024 · The current language in the IMC 602.2.1 Materials within plenums, says “…materials within plenums shall be noncombustible or shall be listed and labeled as having a flame spread index of not more than 25 and a smoke-developed index of not more than 50 when tested in accordance with ASTM E 84 or UL 723.”
Witryna602.2.1 Materials exposed within plenums. Except as requiredbySections602.2.1.1 through 602.2.1.5, materials within plenums shall be noncombustible or shall have a flame spread index of not more than 25 and a smoke-devel-2006 VIRGINIA MECHANICAL CODE 6-1 06_Va_Mech_2006.pS 1 Witryna3 sie 2024 · FyreWrap® 0.5 Plenum has been tested as installed around combustible items and has passed both ASTM E84 and UL1887 to ensure compliance with compliance with 2015 IMC section 602.2.1.
Witryna18-28-602.2.1 Materials exposed within plenums. Materials exposed within plenums shall be noncombustible or shall be listed and labeled as having a flame spread index of not more than 25 and a smoke-developed index of not more than 50 when tested in accordance with ASTM E 84 or UL 723. Witryna602.2.1 Materials Within Plenums. Except as required by Sections 602.2.1.1 through 602.2.1.8, materials within plenums shall be noncombustible or shall be listed and …
Witryna25 sie 2003 · What if any is the size limit for a non-plenum rated material to be used in a plenum environment? For example, the plastic retainer strips that come with J-hooks, or nylon pull string. ryan_618 Senior Member. Location Salt Lake City, Utah. Aug 25, 2003
WitrynaExcept as required by IMC Sections 602.2.1.1 through 602.2.1. 6, materials within plenums shall be noncombustible or shall have a flame spread index of not more … bivona child advocacy summitWitryna9 sie 2024 · Similarly, IMC Section 602.2.1 requires materials exposed within plenums to be noncombustible or to have a flame spread index not more than 25 and a smoke … dateformat.parse unknown sourceWitrynaIMC Interpretation No. 64-17 Issued: 05-01-2024 ME_15_64_17 602.2.1 Materials within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.7, … date format outsystemsWitryna2024-0513 Town of Clayton Building Inspections 2024 NCMC 602.2.1 Materials within plenums Author: Carl Martin Subject: 2024-0513 Town of Clayton Building Inspections 2024 NCMC 602.2.1 Materials within plenums Keywords: 2024-0513 Town of Clayton Building Inspections 2024 NCMC 602.2.1 Materials within plenums Created Date: … date format phpmyadminWitryna602.2.1 Materials within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.7, materials within plenums shall be noncombustible or shall be listed and … bivona child advocacyWitryna602.2.1 Materials within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.6, materials within ple - nums shall be noncombustible or shall have a flame … date format outlookWitryna5 paź 2010 · Hi- IMC 602.2.1 says: Materials within plenums. Except as required by Sections 602.2.1.1 through 602.2.1 .6, materials within plenums shall be … bivona christmas light show